Datasheet

Diode Lasers

Fiber-Coupled Tailored Mini-Bars

Product image of Fiber-Coupled Tailored Mini-Bars

Through the optimization of semiconductor chip structures and optical parameters, Coherent T-Bar architecture delivers high beam quality and high power using standard micro-optics, all assembled with automated processes. The tailored bar-based products are available at 6xx nm, 793 nm, and 9xx nm, with power levels from 40 W up to 2 kW.

Features

  • Ho-doped core - Optimized for 2 µm operation
  • NuCOAT fluoroacrylate coating - Provides durability in extreme environments
  • High pump absorption - Reduces required fiber length
  • Proof tested to > 100 kpsi - Ensures long-term reliability
  • RoHS compliant

Applications

  • High power CW and pulsed fiber lasers
  • Eye-safe medical lasers
  • Military LIDAR systems
  • Material processing
Parameter MDL969FCTBAR240IS58.1SMAF202VBG
Package Fiber-Coupled Tailored Mini-Bars
OPTICAL PARAMETERS1
Center Wavelength Range3 (nm) 969
Center Wavelength Tolerance3 (nm) ±0.6
Output Power2 (W) 240
Operating Condition CW
Spectral Width (90% power content) (nm) ≤1
Slope Efficiency (W/A) ≥6.5
Numerical Aperture (NA) 0.215 ±0.005
FIBER PARAMETERS5
Fiber Core Diameter (μm) 202 ±2
Fiber Cladding Diameter (μm) 242 ±2 (Modestrip)
Fiber Coating Diameter (μm) 400 ±25
Fiber Loose Tubing Diameter (mm) 3
Fiber Length (m) 2
Fiber Termination SMA
ELECTRICAL PARAMETERS1
Power Conversion Efficiency (%) ≥46
Threshold Current (ITH) (A) ≤4
Operating Current (IOP) (A) ≤40
Operating Voltage (VOP) (V) ≤15
THERMAL PARAMETERS
Operating Temperature Range2,3,4 (°C) +20 to +25
Coolant Temperature +20 to +25
Coolant Flow Rate ≥150
MECHANICAL PARAMETERS
Size (mm3) [W x D x H] See Drawing
Weight (kg) ~1
Purity Tap Water

Notes:
1.2 Data at 25°C cooling water temperature. [IS45 Red and all other wavelengths]
2. Reduced lifetime if used above nominal operating conditions.
3. Others available upon request.
4. A non-condensing environment is required for storage and operation below the ambient dew point.
5. It is essential for the module to work correctly that the cooling water temperature and flow rate are monitored as an interlock for interrupting the laser current immediately if a value exceeds or falls below the given parameter.
6. Non-detachable fiber.