Ask a Question
Coherent
Innova 300C
Innova 300C
INNOVA® 300C

I-300C is ideal for scientific or commercial/ industrial/OEM use in applications and processes where higher UV or visible output is required.

For the ultimate in single-wavelength performance, I-300C adds additional performance enhancement for dedicated UV or visible operation, single-frequency operation, and optimized beam quality.

I-300C Key attributes:

  • Multiline output power to 6 W
  • Argon or Krypton models
  • SuperInvar resonator for superb beam-pointing and single-frequency performance
  • Distributed microprocessors with compact digital remote control for ease-of-use
  • Innova Series V plasma tube for long, trouble-free lifetime
  • Linear passbank power supply for lowest noise operation
  • Multiline output to 8 W tunable, 10 W in a pumping configuration
  • Argon or Krypton models, including Krypton models optimized for Violet or UV wavelengths
  • PowerTrack™ automatic active cavity stabilization for maximum power, best transverse mode, and lowest beam noise
  • ModeTrack/ModeTune™ etalon stabilization for mode-hop-free, single-frequency performance over a wide temperature range
  • Several Sealed-Mirror models optimized for UV-only operation.
Features & Benefits

Power Specifications1
I-304 I-305 I-306 I-307 I-308
Argon Systems with Dual Brewster Window Tubes
Multiline Blue/Green2
4.0
5.0
6.0
7.0
8.0
Multiline UV3
0.20
0.40
0.50
0.60
0.75
1090.0
0.04
0.05
0.07
0.07
0.10
528.7
0.20
0.35
0.42
0.42
0.55
514.5
1.70
2.00
2.40
2.40
3.20
501.7
0.30
0.40
0.48
0.48
0.48
496.5
0.50
0.60
0.72
0.72
0.95
488.0
1.30
1.50
1.80
1.80
2.40
476.5
0.50
0.60
0.72
0.72
0.95
472.7
0.12
0.20
0.24
0.24
0.24
465.8
0.10
0.15
0.18
0.18
0.18
457.9
0.25
0.35
0.42
0.42
0.56
454.5
0.05
0.12
0.14
0.14
0.14
UV 363.8
0.07
0.14
0.17
0.19
0.25
UV 351.1
0.07
0.14
0.17
0.19
0.25

I-310
Argon Systems with Sealed Mirror - Visible Region
Multiline Visible2
10.0

I-324
I-325
I-326
I-328
Argon Systems with Sealed Mirror - UV Region
Multiline UV 3
0.20
0.40
0.50
1.00
UV 363.8
0.07
0.14
0.18
0.36
UV 351.1
0.09
0.18
0.22
0.44

I-304
I-305
I-306
I-307
I-308
Argon Single Frequency Powers - Visible Region
514.5
1.00
1.20
1.40
1.40
1.90
488.0
0.75
0.90
1.10
1.10
1.40
457.9
0.15
0.20
0.25
0.25
0.35

I-304
I-305
I-306
I-307
I-308
Argon Single Frequency Powers - UV Region
UV 363.8
0.04
0.08
0.10
0.11
0.15
UV 351.1
0.04
0.08
0.10
0.11
0.15

Power Specifications1
I-301 I-302
Krypton Systems with Dual Brewster Window Tubes
Multiline Red
1.0
1.0
Multiline IR
4.0
5.0
Multiline Violet
4.0
5.0
Multiline UV3
0.20
0.40
1090.0
0.04
0.05
528.7
0.20
0.35
514.5
1.70
2.00
501.7
0.30
0.40
496.5
0.50
0.60
488.0
1.30
1.50
476.5
0.50
0.60
472.7
0.12
0.20
465.8
0.10
0.15
457.9
0.25
0.35
454.5
0.05
0.12
UV 363.8
0.07
0.14
UV 351.1
0.07
0.14

1 All powers are listed in Watts. Guaranteed power specifications for standard systems are indicated in bold print. All other specifications are available at an additional charge, which includes the necessary optics and testing. All output powers, except multiline visible, UV and IR powers, refer to TEM00 operation. The Innova 307 at 514.5 nm and 488.0 nm exhibits an M2 value specified to be < 1.1.

2 Multiline visible powers range from 457.9 nm to 514.5 nm.

3 Multiline UV powers range from 333.4 nm to 363.8 nm for argon systems, and from 337.5 nm to 356.4 nm for krypton systems.

Call 1-800-227-8840


Outside the U.S. 1-408-764-4983

Coherent has locations across the globe that are available to provide support for any product, service or inquiry.

Visit our Contact Page to connect with any of our global sites.


Corporate Headquarters
Coherent Inc.
5100 Patrick Henry Drive
Santa Clara, CA 95054 USA

email: tech.sales@coherent.com

Send Us a Message

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions