Ask a Question
Coherent
PowerMax-Pro USB/RS Sensors with Laptop PowerMax-Pro USB/RS Sensors
PowerMax-Pro USB/RS Sensors
PowerMax-Pro USB/RS Sensors

New PowerMax-Pro incorporating LabMax-Pro instrumentation directly within the sensor cable.

PowerMax-Pro USB and RS sensors incorporate LabMax-Pro instrumentation directly within the sensor cable. Similar to other Coherent USB and RS sensors, this configuration offers a smaller form factor for use inside laser processing systems or production lines. Additionally, the cost of annual calibration is half that of a separate meter and sensor system. The PowerMax-Pro USB and RS sensors operate with LabMax-Pro PC applications software (included).

PowerMax-Pro USB and RS Sensors

PowerMax-Pro (Patent #9,012,848) represents a dramatic technological advancement in laser power sensing that utilizes a thin-film detector only microns thick which rapidly senses thermal changes due to incident laser energy. The result is a measurement response time below 10 μs, as compared to over 1 second for traditional thermopiles . These detectors can operate at high power over a spectral range as broad as 300 nm to 11 μm, and incorporate a large 30 mm x 30 mm active a rea.

The high response speed of PowerMax-Pro sensors is particularly advantageous in a wide range of commercial and medical applications. It enables nearly instant measurement of CW laser power, resulting in increased throughput, and also supports high resolution analysis of modulated laser pulse shapes resulting in improved laser characterization and process control.

Specifications PowerMax-Pro USB/RS
150 HD 150 HD Nano 150F HD 150F HD Nano 150 BB 150F BB
Wavelength Range 400 nm to 1100 nm; 9 μm to 11 μm 400 nm to 1100 nm; 9 μm to 11 μm 400 nm to 1100 nm; 9 μm to 11 μm 400 nm to 1100 nm; 9 μm to 11 μm 400 nm to 11 μm 400 nm to 11 μm
Power Range
Water-cooled 200 mW to 150W 200 mW to 150W - - 200 mW to 150W -
Air Cooled 100 mW to 17W 100 mW to 17W 200 mW to 150W 200 mW to 150W 100 mW to 17W 100 mW to 17W
Maximum Peak Power (W) 200 200 200 200 200 200
(use for >1 μsec pulses up to CW)
Maximum Intermittent Power (W) (<5 min.) 65 (air-cooled) 65 (air-cooled) 150 (maximum) 150 (maximum) 65 (air-cooled) 65 (air-cooled)
Noise Equivalent Power (mW)
Standard Mode <4 <4 <4 <4 <4 <4
High Speed Mode <8 <8 <8 <8 <8 <8
Snapshot Mode <16 <16 <16 <16 <16 <16
Maximum Power Density (kW/cm²) 0.2 (150W) 0.2 (150W) 0.2 (150W) 0.2 (150W) 0.2 (150W) 0.2 (150W)
Maximum Peak Power Density (kW/cm²) 14 14 14 14 14 14
Maximum Energy Density (J/cm²) 33 (10 ns; 1064 nm) 33 (10 ns; 1064 nm) 33 (10 ns; 1064 nm) 33 (10 ns; 1064 nm) 33 (10 ns; 1064 nm) 33 (10 ns; 1064 nm)
Rise & Fall Time (μs) ≤10 ≤350 ≤10 ≤350 ≤50 ≤50
Detector Coating HD HD HD HD BB BB
Active Area (mm) 30 x 30 30 x 30 30 x 30 30 x 30 30 x 30 30 x 30
Minimum Beam Size (mm) 2.0 (1.0 mm - up to 3% error) 2.0 (1.0 mm - up to 3% error) 2.0 (1.0 mm - up to 3% error) 2.0 (1.0 mm - up to 3% error) 2.0 (1.0 mm - up to 3% error) 2.0 (1.0 mm - up to 3% error)
Calibration Uncertainty (%) (k=2) ±2 ±2 ±2 ±2 ±2 ±2
Power Linearity (%) ±5 ±5 ±5 ±5 ±5 ±5
Spectral Compensation Accuracy (%) ±3 ±3 ±3 ±3 ±3 ±3
Spatial Uniformity (%) ±5 ±5 ±5 ±5 ±5 ±5
(center 75% of aperture; 2.5 mm beam)
Calibration Wavelength (nm) 810 810 810 810 810 810
Cooling Method Water/Air (intermittent) Water/Air (intermittent) Fan Fan Water/Air (intermittent) Water/Air (intermittent)
Cable Type USB/RS-232 USB/RS-232 USB/RS-232 USB/RS-232 USB/RS-232 USB/RS-232
Cable Length 4.2m (13.8 ft.) 4.2m (13.8 ft.) 4.2m (13.8 ft.) 4.2m (13.8 ft.) 4.2m (13.8 ft.) 4.2m (13.8 ft.)
Part Number
USB 1295921 1330510 1295920 1330544 1342379 1342380
RS-232 1295923 1330545 1295922 1330546 1342381 1342382

Drawing Packages
Click the links below to download a complete drawing package for these products.

Related Materials

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.