Customers who have purchased a Coherent laser valued at greater than $5,000 within the past 12 months are entitled to a 20% discount off the local domestic list price on Coherent laser measurement products.
Below are the list of matrix recommendations or download the matrix recommendations - measurement products for use with Coherent lasers. Please call (800) 343-4912 or email LMC.Sales@coherent.com for more information.
CO2 Diamond Laser |
Wavelength (mm) |
Power Meter |
Power Sensor |
C-30 |
10.6 |
FieldMaxII-TO |
PM30 |
C-40, C-55, C-70 |
10.6 |
FieldMaxII-TO |
PM150 |
G-100, G-150 |
10.2 to 10.7 |
FieldMaxII-TO |
PM150 |
G-100i |
9.4± 0.3 |
FieldMaxII-TO |
PM150 |
K-250, K-225I, K-300 |
10.4 to 10.8 |
FieldMaxII-TO |
PM300F-19 |
E-400, K-500 |
10.2 to 10.8 |
FieldMaxII-TO |
PM1K |
GEM SELECT 50, 100 |
10.6 nominal |
FieldMaxII-TO |
PM150 |
EOM-10 |
10.6 |
FieldMaxII-TO |
PM10 |
MID-IR-2 |
10.6 |
FieldMaxII-TO |
PM10 |
SIFIR |
40 to 1020 |
FieldMaxII-TO |
PS10 |
Diode Laser |
Wavelength (nm) |
Power Meter |
Power Sensor |
CUBE |
375 to 785 |
FieldMaxII-TO |
PS10 |
Radius |
375 to 635 |
FieldMaxII-TO |
PS10 |
All Laser Diode Modules |
FieldMaxII-TO |
PS10 |
|
FAP |
780 to 840 |
LabMax-TOP |
LM-150FS + SMA adapter |
Duo FAP |
785 to 820 |
LabMax-TOP |
LM-150FS + SMA adapter |
Quattro FAP |
790 to 980 |
LabMax-TOP |
LM-150FS + SMA adapter |
Highlight 5000L |
805 to 940 |
FieldMaxII-TO |
PM5K-100 |
Highlgith 1000F |
975 |
FieldMaxII-TO |
PM1K |
Diode-Pumped Solid-State Lasers (CW) |
Wavelength (nm) |
Power Meter |
Power Sensor |
Azure |
266 |
FieldMaxII-TO |
PM10X or PS10 |
Compass 1064 |
1064 |
FieldMaxII-TO |
PM10 |
Compass 115M, 215M, 315M |
532 |
FieldMaxII-TO |
PS10 |
Compass 561 |
561 |
FieldMaxII-TO |
PS10 |
Genesis |
355, 532 |
FieldMaxII-TO |
PS10 |
MBD 266 |
266 |
FieldMaxII-TO |
PM10X or PS10 |
Paladin 355 |
355 |
FieldMaxII-TO |
PM10X |
Sapphire 460, 488 |
460.488 |
FieldMaxII-TO |
PM10, PS10 |
Sapphire 561 |
561 |
FieldMaxII-TO |
PS10 |
Verdi V2, V5, V6, V8 |
532 |
FieldMaxII-TO |
PM30 |
Verdi V10 , V12, V18 |
532 |
FieldMaxII-TO |
PM30 |
Verdi IR |
1064 |
FieldMaxII-TO |
PM30 |
Ion Lasers |
Wavelength (nm) |
Power Meter |
Power Sensor |
Innova (<1W) |
200 to 1100 |
FieldMaxII-TO |
PS10 |
Innova (>1W) |
200 to 1100 |
FieldMaxII-TO |
PM10 |
Mantis |
800 |
FieldMaxII-TOP/LabMax-TOP |
PM10 or PS10 |
Micra |
750 to 860 |
FieldMaxII-TOP/LabMax-TOP |
PM10 or PS10 |
Mira |
700 to 980 |
FieldMaxII-TOP/LabMax-TOP |
PM10 |
Vitesse |
800 |
FieldMaxII-TOP/LabMax-TOP |
PM10 or PS10 |
Chameleon |
680 to 1080 |
FieldMaxII-TOP/LabMax-TOP |
PM10 |
Mira OPO |
500 to 1600 |
FieldMaxII-TOP/LabMax-TOP |
PS10 |
| Diode-Pumped Solid-State Lasers (Pulsed) | Wavelength (nm) |
Power Meter |
Power Sensor |
Energy Meter |
Energy Sensor |
| AVIA (<10W) | 266, 355 |
FieldMaxII-TO |
PM10X |
- |
- |
| AVIA (10W TO 30W) | 355, 532 |
FieldMaxII-TO |
PM30X |
- |
- |
| AVIA (>30W) | 532 |
FieldMaxII-TO |
PM150 |
- |
- |
| MATRIX 1064 | 1064 |
FieldMaxII-TO |
PM10 |
- |
- |
| MATRIX 355 | 355 |
FieldMaxII-TO |
PM10X |
- |
- |
| PRISMA (<10W) | 532,1064 |
FieldMaxII-TO |
PM10 |
- |
- |
| PRISMA (>10W) | 532,1064 |
FieldMaxII-TO |
PM30 |
- |
- |
| Talisker | 355,532,1064 |
FieldMaxII-TO |
PM30 |
- |
- |
| Vector | 5321064 |
FieldMaxII-TO |
PM30 |
- |
- |
| Q-Switched Lasers | Wavelength (nm) |
Power Meter |
Power Sensor |
Energy Meter |
Energy Sensor |
| Evolution (<30W) | 527 |
FieldMaxII-TOP |
PM30 |
LabMax-TOP |
J-25MT-10KHZ plus medium heat sink |
| Evolution (>30W) | 527 |
FieldMaxII-TOP |
PM150 |
- |
- |
| Ultrafast Amplifiers | Wavelength (nm) |
Power Meter |
Power Sensor |
Energy Meter |
Energy Sensor |
| OPerA Solo | 240 nm to 20 µm |
FieldMaxII-TOP |
PS10/PM10 |
LabMax-TOP |
J-10MT-10KHZ (<1 mJ pump) |
J-10MB-HE (>1 mJ pump) |
|||||
| TOPAS | 240 nm to 20 µm |
FieldMaxII-TOP |
PS10/PM10 |
LabMax-TOP |
J-10MT-10KHZ (<1 mJ pump) |
J-10MB-HE (>1 mJ pump) |
|||||
| OPA 9400, 9800, DFG | 480 nm to 10,000 nm |
FieldMaxII-TOP |
PS10/PM10 |
- |
- |
| Legend (<10W) | 775 nm to 845 nm |
FieldMaxII-TOP |
PS10/PM10 |
LabMax-TOP |
J-25MT-10KHZ |
| Legend (>10W) | 800 nm |
FieldMaxII-TOP |
PM30 |
LabMax-TOP |
J-25MT-10KHZ plus medium heat sink |
| Libra | 800 nm |
FieldMaxII-TOP |
PM10 |
LabMax-TOP |
J-25MT-10KHZ |
| RegA | 770 nm to 850 nm |
FieldMaxII-TOP |
PS10 |
- |
- |
| Hidra | 800 nm |
FieldMaxII-TOP |
PM10V1 |
FieldMaxII-TOP |
J-50MT-10KHZ |
| Excimer Lasers | Wavelength (nm) |
Power Meter |
Power Sensor |
Energy Meter |
Energy Sensor |
| BraggStar | 193, 248 |
FieldMaxII-TO |
PM10X |
LabMax-TOP |
J-25MT-10KHZ |
| COMPexPro F2 | 157 |
FieldMaxII-TO |
PM10X |
FieldMaxII-TOP |
J-25MUV-193 |
| COMPexPro 50,102,110,201,205 | 193 |
FieldMaxII-TO |
PM150-50XC |
FieldMaxII-TOP |
J-50MUV-193 |
| ExciStar XS 500 | 193, 248 |
FieldMaxII-TO |
PM30X |
LabMax-TOP |
J-25MT-10KHZ plus small heat sink |
| IndyStar | 193, 248 |
FieldMaxII-TO |
PM150-50XC |
LabMax-TOP |
J-25MT-10KHZ plus small heat sink |
| LPFpro 205, 220 | 157 |
FieldMaxII-TO |
PM150-50XC |
FieldMaxII-TOP |
J-50MUV-193 |
| LPXpro 210, 220, 305 | 193, 248, 308, 351 |
FieldMaxII-TO |
PM150X, PM150-50XC |
- |
- |
| Xantos XS | 157, 193, 248, 351 |
FieldMaxII-TO |
PM10X |
LabMax-TOP |
J-25MT-10KHZ |
| LAMDA SX-Series | 248, 308 |
FieldMaxII-TO |
PM300F-50X, PM1KX1 |
- |
- |
Literature & Documentation . . .
| WARNING: Be aware of job search related scams. Cyber scammers have been posting fraudulent job openings for Coherent on several internet job sites. These positions include acting as "Regional Representatives." These scammers ask job applicants to wire money to individuals in foreign countries. DO NOT DO SO. Coherent does not ask job applicants to wire money to anyone. If you are either the victim of this scammer or if you have received a request to send money to anyone in connection with a Coherent job, please file a formal complaint at www.IC3.gov, which is the website maintained by the Internet Crime Complaint Center, a partnership of the FBI, the National White Collar Crime Center, and Bureau of Justice Assistance. |